public class MonitorNotification extends Notification
Provides definitions of the notifications sent by monitor MBeans.
The notification source and a set of parameters concerning the monitor MBean's state need to be specified when creating a new object of this class. The list of notifications fired by the monitor MBeans is the following:
public static final String OBSERVED_OBJECT_ERROR
Notification type denoting that the observed object is not registered in the MBean server. This notification is fired by all kinds of monitors.
The value of this notification type is jmx.monitor.error.mbean
.
public static final String OBSERVED_ATTRIBUTE_ERROR
Notification type denoting that the observed attribute is not contained in the observed object. This notification is fired by all kinds of monitors.
The value of this notification type is jmx.monitor.error.attribute
.
public static final String OBSERVED_ATTRIBUTE_TYPE_ERROR
Notification type denoting that the type of the observed attribute is not correct. This notification is fired by all kinds of monitors.
The value of this notification type is jmx.monitor.error.type
.
public static final String THRESHOLD_ERROR
Notification type denoting that the type of the thresholds, offset or modulus is not correct. This notification is fired by counter and gauge monitors.
The value of this notification type is jmx.monitor.error.threshold
.
public static final String RUNTIME_ERROR
Notification type denoting that a non-predefined error type has occurred when trying to get the value of the observed attribute. This notification is fired by all kinds of monitors.
The value of this notification type is jmx.monitor.error.runtime
.
public static final String THRESHOLD_VALUE_EXCEEDED
Notification type denoting that the observed attribute has reached the threshold value. This notification is only fired by counter monitors.
The value of this notification type is jmx.monitor.counter.threshold
.
public static final String THRESHOLD_HIGH_VALUE_EXCEEDED
Notification type denoting that the observed attribute has exceeded the threshold high value. This notification is only fired by gauge monitors.
The value of this notification type is jmx.monitor.gauge.high
.
public static final String THRESHOLD_LOW_VALUE_EXCEEDED
Notification type denoting that the observed attribute has exceeded the threshold low value. This notification is only fired by gauge monitors.
The value of this notification type is jmx.monitor.gauge.low
.
public static final String STRING_TO_COMPARE_VALUE_MATCHED
Notification type denoting that the observed attribute has matched the "string to compare" value. This notification is only fired by string monitors.
The value of this notification type is jmx.monitor.string.matches
.
public static final String STRING_TO_COMPARE_VALUE_DIFFERED
Notification type denoting that the observed attribute has differed from the "string to compare" value. This notification is only fired by string monitors.
The value of this notification type is jmx.monitor.string.differs
.
public ObjectName getObservedObject()
Gets the observed object of this monitor notification.
public String getObservedAttribute()
Gets the observed attribute of this monitor notification.
public Object getDerivedGauge()
Gets the derived gauge of this monitor notification.
public Object getTrigger()
Gets the threshold/string (depending on the monitor type) that triggered off this monitor notification.
© 1993–2017, Oracle and/or its affiliates. All rights reserved.
Documentation extracted from Debian's OpenJDK Development Kit package.
Licensed under the GNU General Public License, version 2, with the Classpath Exception.
Various third party code in OpenJDK is licensed under different licenses (see Debian package).
Java and OpenJDK are trademarks or registered trademarks of Oracle and/or its affiliates.