Parameter | Choices/Defaults | Comments |
---|---|---|
baud - |
| This is the baud rate to assign to the port. 0=300, 1=1200, 2=2400, 3=4800, 4=9600, 5=19200, 6=38400, 7=57600, 8=115200, 9=230400, 10=460800 |
break_allow - | This is if the break character is allowed to be passed through the port, 0=Off, 1=On | |
cmd - |
| This is the Admin Mode to assign to the port, 0=Deny, 1=Permit. |
cpm_password - / required | This is the Password of the WTI device to send the module. | |
cpm_url - / required | This is the URL of the WTI device to send the module. | |
cpm_username - / required | This is the Username of the WTI device to send the module. | |
echo - | -This is the command echo parameter to assign to the port, 0=Off, 1=On | |
handshake - |
| This is the handshake to assign to the port, 0=None, 1=XON/XOFF, 2=RTS/CTS, 3=Both. |
logoff - | This is the logout character to assign to the port If preceded by a ^ character, the sequence will be a control character. Used if seq is set to 0 or 1 | |
mode - |
| This is the port mode to assign to the port, 0=Any-to-Any. 1=Passive, 2=Buffer, 3=Modem, 4=ModemPPP. |
parity - |
| This is the parity to assign to the port, 0=7-None, 1=7-Even, 2=7-Odd, 3=8-None, 4=8-Even, 5=8-Odd. |
port integer / required | This is the port number that is getting the action performed on. | |
portname - | This is the Name of the Port that is displayed. | |
seq - |
| This is the type of Sequence Disconnect to assign to the port, 0=Three Characters (before and after), 1=One Character Only, 2=Off |
stopbits - |
| This is the stop bits to assign to the port, 0=1 Stop Bit, 1=2 Stop Bit. |
tout - |
| This is the Port Activity Timeout to assign to the port, 0=Off, 1=5 Min, 2=15 Min, 3=30 Min, 4=90 Min, 5=1 Min. |
use_https boolean |
| Designates to use an https connection or http connection. |
use_proxy boolean |
| Flag to control if the lookup will observe HTTP proxy environment variables when present. |
validate_certs boolean |
| If false, SSL certificates will not be validated. This should only be used on personally controlled sites using self-signed certificates. |
Note
groups/cpm
in module_defaults
to set common options used between CPM modules.# Set Serial Port Parameters - name: Set the Port Parameters for port 2 of a WTI device cpm_serial_port_config: cpm_url: "nonexist.wti.com" cpm_username: "super" cpm_password: "super" use_https: true validate_certs: false port: "2" portname: "RouterLabel" baud: "7" handshake: "1" stopbits: "0" parity: "0" mode: "0" cmd: "0" seq: "1" tout: "1" echo: "0" break_allow: "0" logoff: "^H" # Set Serial Port Port Name and Baud Rate Parameters - name: Set New port name and baud rate (115k) for port 4 of a WTI device cpm_serial_port_config: cpm_url: "nonexist.wti.com" cpm_username: "super" cpm_password: "super" use_https: true validate_certs: false port: "4" portname: "NewPortName1" baud: "8"
Common return values are documented here, the following are the fields unique to this module:
Key | Returned | Description |
---|---|---|
data string | always | The output JSON returned from the commands sent |